.. _ApiFlowChecksExamples target: Writing Custom Flow Scripts: Guide and Examples =============================================== This page explains, step by step, how a custom flow script is made and then shows ready-to-use examples, from the simplest to the more complete ones. Copy an example, change the values marked in the comments, save it in `/etc/ntopng/custom_checks/flows/` and restart ntopng. The full list of options and functions is in :ref:`ApiFlowChecks target`. How a script works ------------------ ntopng looks at every flow (a conversation between a client and a server). For each flow, it asks your script: *"is there something wrong here?"*. Your script answers by calling `flow.triggerAlert("message")` when it finds a problem, or by doing nothing when the flow is fine. A script has two parts: 1. **Which flows to look at** (`filter`): e.g. only Modbus, only port 502, only the hosts of the pool *OT Devices*. ntopng applies the filter for you, very quickly, and gives the script only these flows. 2. **What to check** (`check`): a few lines that read the flow (its addresses, ports, bytes, protocol...) and decide whether to raise the alert. The smallest working script is: .. code:: lua return { title = "Telnet in use", filter = { srv_port = 23 }, check = function(flow) flow.triggerAlert("Telnet connection to " .. flow.srv()) end, } Read it as: *"for every flow towards port 23, raise the alert Telnet in use with the message Telnet connection to "*. The filter does all the work, the check only raises the alert. Lua in five minutes ------------------- You need very little Lua to write a script. This is all of it: .. code:: lua -- Two dashes start a comment: ntopng ignores the rest of the line. -- A variable: a name that holds a value. Always write "local" in front of it. local max_bytes = 1000000 -- a number local plc_address = "10.0.0.5" -- a text (string), always in quotes -- Join texts with two dots local message = "Too much traffic to " .. plc_address -- Compare: == (equal), ~= (different, NOT !=), <, >, <=, >= -- Combine conditions with: and, or, not if flow.bytes() > max_bytes and flow.srv() == plc_address then flow.triggerAlert(message) end -- every "if" closes with "end" -- if / elseif / else if flow.srv_port() == 502 then -- ... elseif flow.srv_port() == 102 then -- ... else -- ... end -- A list of allowed values (a "set"): the value in square brackets, then "= true" local allowed_clients = { ["10.0.0.10"] = true, ["10.0.0.11"] = true, } if not allowed_clients[flow.cli()] then -- true when the client is NOT in the list flow.triggerAlert("Client not allowed: " .. flow.cli()) end Things to remember: - Inside `return { ... }` every entry ends with a comma: `title = "...",` `score = 100,` `check = function(flow) ... end,` - Texts go in double quotes; numbers do not (`502`, not `"502"`). - `function(flow) ... end`, `if ... then ... end`, `for ... do ... end`: every block closes with `end`. - Upper and lower case matter: `flow.srv()` works, `flow.SRV()` does not. - A value that is not there is `nil`. Joining `nil` to a text is an error: use `tostring(value)` when a value may be missing, e.g. `"Query: " .. tostring(query)`. Choosing the flows: the filter ------------------------------ The filter is the most important part: it decides which flows reach the script, and it is evaluated by ntopng at no cost. Write as narrow a filter as you can. .. code:: lua filter = { srv_port = 502, -- server port 502 ip = { "10.10.0.0/16", "192.168.1.5" }, -- client or server in 10.10.0.0/16, or 192.168.1.5 pool = "OT Devices", -- client or server in the host pool "OT Devices" }, Rules: - Every field you write must match (it is an AND): the example selects the flows on port 502 **and** with an address in the list **and** with a host in the pool. - A field with a list matches when any of its values does (it is an OR): `srv_port = { 502, 503 }` is port 502 or 503. - Fields you do not write match every flow. A script without `filter` receives all the flows: avoid it. Available fields: `cli_ip`, `srv_ip`, `ip`, `cli_port`, `srv_port`, `port`, `l4_proto`, `l7_proto`, `cli_pool`, `srv_pool`, `pool`. `cli_` means the client, `srv_` the server, no prefix either of them. `exclude` has the same fields and does the opposite: the flows matching it are skipped. For instance ``exclude = { cli_ip = "10.0.0.250" }`` ignores the flows of a monitoring server. **Host pools** can be written by name (`"OT Devices"`, exactly as shown in *Pools* > *Host Pools*, upper and lower case included) or by number (the pool id, e.g. `3`). The hosts that are not in any pool belong to the `Default` pool (id `0`). The names are read when the script is loaded: after creating or renaming a pool, disable and enable again *Flow User Check Script* (or restart ntopng) so that the scripts are loaded again. A pool name that does not exist disables the script, and the ntopng log says so. When to run: the hooks ---------------------- `hooks` says when ntopng calls the script for a flow: - `detected`: once, when ntopng recognises the application protocol of the flow (at the start of the flow). - `periodic`: every few seconds while the flow is active. - `end`: once, when the flow ends. Without `hooks` the script runs on all three. Use `detected` to count connections (each flow counts once), and `periodic` / `end` to check values that grow during the flow (bytes, function codes). A script that calls `flow.triggerAlert` several times on the same flow does not create duplicate alerts. Examples -------- Each example is a complete file. Save it with a name ending in `.lua`, e.g. `/etc/ntopng/custom_checks/flows/ot_internet.lua`. Example 1: OT devices talking to the Internet ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ The PLCs are in the host pool *OT Devices*: they must only talk inside the plant. Alert when one of them, as a client, contacts a remote (non local) host. .. code:: lua return { title = "OT device contacts the Internet", score = 100, hooks = { "detected" }, filter = { cli_pool = "OT Devices" }, -- change it to the name of your pool check = function(flow) -- "local@remote": local client, remote server if flow.direction() == "local@remote" then flow.triggerAlert("OT device " .. flow.cli() .. " contacted " .. flow.srv() .. ":" .. flow.srv_port()) end end, } Example 2: only allowed clients may talk to the PLCs ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ The PLCs are in the pool *PLC*, and only the two engineering workstations may connect to them. .. code:: lua -- The workstations allowed to connect to the PLCs local ALLOWED_CLIENTS = { ["10.0.0.10"] = true, ["10.0.0.11"] = true, } return { title = "Unauthorised access to PLC", score = 150, hooks = { "detected" }, filter = { srv_pool = "PLC" }, check = function(flow) if not ALLOWED_CLIENTS[flow.cli()] then flow.triggerAlert(flow.cli() .. " connected to PLC " .. flow.srv() .. " on port " .. flow.srv_port()) end end, } Counting over time: counter --------------------------- Many detections are "too many times in a while": too many connections per minute, a command repeated too often. A single flow does not know about the other flows, so every script receives a ready-made helper, `counter`, that keeps counts across flows. Nothing to install or `require`: it is always there. - | **counter.inc(key, seconds [, amount])** | Adds `amount` (default 1) to the counter called `key` and returns its new value. The counter starts from 0 and is cleared `seconds` after its first `inc` (default 60): then the count starts again from 0. - | **counter.get(key)** | The current value of `key`, without changing it (0 when it was never used or has been cleared). - | **counter.reset(key)** | Clears `key` now. The `key` is a text you choose, and decides *what* is counted. Build it from the flow: .. code:: lua counter.inc(flow.cli(), 60) -- per client, in 1 minute counter.inc(flow.srv(), 3600) -- per server, in 1 hour counter.inc(flow.cli() .. ">" .. flow.srv(), 60) -- per client-server pair, in 1 minute counter.inc(flow.srv() .. "/fc65", 60, 10) -- add 10 to the "function code 65 on this server" count Good to know: - The time window is fixed, not sliding: with 60 seconds, a count that starts at 10:00:20 is cleared at 10:01:20. - Each script has its own counters: two scripts using the same key do not see each other's counts. The counters are also kept per interface, and they are cleared when the scripts are loaded again. - Use the hook `detected` when counting flows (each flow is counted once). The installed example `modbus_function_code_rate.lua` shows how to count the Modbus function codes of all the flows of a PLC. Example 3: too many connections per minute ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Alert when a client opens more than 30 Modbus connections in one minute (a scan or a misbehaving HMI). The key is the client address, so each client has its own counter. The hook is `detected`, so that each flow is counted once. .. code:: lua local MAX_CONNECTIONS_PER_MINUTE = 30 return { title = "Modbus connection burst", hooks = { "detected" }, filter = { srv_port = 502, l4_proto = "TCP" }, check = function(flow) local connections = counter.inc(flow.cli(), 60) if connections > MAX_CONNECTIONS_PER_MINUTE then flow.triggerAlert(flow.cli() .. " opened " .. connections .. " Modbus connections in the last minute") end end, } OT protocols ------------ In a typical OT installation nProbe analyses the traffic of the plant and sends the flows to ntopng, with the information of the OT protocols. A script reads it in two ways: - `flow.ot()`: the OT protocols known to ntopng (Modbus, S7Comm, PROFINET, IEC 60870-5-104), always with the same structure, both for the flows sent by nProbe and for the traffic captured by ntopng. - `flow.json_info()`: any other field nProbe sends with the flow, e.g. the fields that an nDPI plugin adds to an OT protocol on the nProbe side (see Example 6). This is what `flow.ot()` returns for a Modbus flow (the numbers are the totals since the flow started): .. code:: lua { modbus = { function_codes = { ["3"] = 20, ["65"] = 150 }, -- function code -> number of uses function_codes_transitions = { ["3,65"] = 10 }, -- "from,to" -> number of times registers = { ["100"] = 12, ["40001"] = 3 }, -- register -> number of uses num_exceptions = 7, -- exceptions (errors) returned } } S7Comm (`flow.ot().s7comm`) has `function_codes`, `function_codes_transitions` and `num_exceptions`; PROFINET (`flow.ot().profinet`) also has `operations` (requests, responses ok and responses with errors per operation). A protocol that is not in the flow is `nil`: always check it, as in the examples below. .. warning:: The function codes, transitions and registers are **texts in quotes**: write ``function_codes["65"]``. ``function_codes[65]`` (without quotes) is always `nil`, so the script never raises the alert. The values grow while the flow is active: use the hooks `periodic` and `end`, so the script sees the updated values. The same alert is not repeated on the same flow. Example 4: too many Modbus exceptions ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Alert when a PLC returns more than 5 exceptions in a flow: a client is sending wrong commands, or the PLC is failing. .. code:: lua local MAX_EXCEPTIONS = 5 return { title = "Too many Modbus exceptions", score = 80, hooks = { "periodic", "end" }, filter = { l7_proto = "Modbus", srv_pool = "PLC" }, check = function(flow) local modbus = flow.ot().modbus if not modbus then return end -- no Modbus information (yet) if modbus.num_exceptions > MAX_EXCEPTIONS then flow.triggerAlert(modbus.num_exceptions .. " Modbus exceptions from " .. flow.srv()) end end, } Example 5: a function code used too much, or one that must never be used ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Two rules in one script: some Modbus function codes are allowed only up to a number of uses per flow, others must never be seen. .. code:: lua -- Function code (in quotes) -> maximum number of uses in a flow local MAX_USES = { ["6"] = 50, -- Write Single Register ["16"] = 20, -- Write Multiple Registers } -- Function codes that must never be used local FORBIDDEN = { ["8"] = "Diagnostics", ["65"] = "vendor command 65", } return { title = "Modbus function code not allowed", score = 120, hooks = { "periodic", "end" }, filter = { l7_proto = "Modbus" }, check = function(flow) local modbus = flow.ot().modbus if not modbus then return end for code, uses in pairs(modbus.function_codes) do if FORBIDDEN[code] then flow.triggerAlert("Forbidden function code " .. code .. " (" .. FORBIDDEN[code] .. ") sent to " .. flow.srv()) return end if MAX_USES[code] and uses > MAX_USES[code] then flow.triggerAlert("Function code " .. code .. " used " .. uses .. " times (max " .. MAX_USES[code] .. ")") return end end end, } S7Comm works the same way: use ``flow.ot().s7comm`` and ``filter = { l7_proto = "S7Comm" }``. For instance the S7 function codes ``"40"`` (PLC Control) and ``"41"`` (PLC Stop) start and stop the PLC program and, outside maintenance, must never be seen. Example 6: fields added by nProbe plugins ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ When an nProbe plugin (or an nDPI plugin on the nProbe side) adds fields to an OT protocol, the script reads them with `flow.json_info()`, by the name nProbe gives them. The field names depend on the plugin: to find them, use this script once, read the names in the ntopng log, then delete it. .. code:: lua return { title = "Show the probe fields", hooks = { "end" }, filter = { srv_port = 502 }, -- the flows you are interested in check = function(flow) for name, value in pairs(flow.json_info()) do print(name .. " = " .. tostring(value)) end end, } The log shows lines such as `OT_SETPOINT = 812`. Then check the field: `tonumber` turns it into a number (the probe may send numbers as texts), and is `nil` when the field is missing. .. code:: lua local SETPOINT_MIN, SETPOINT_MAX = 0, 500 local ALLOWED_COMMANDS = { [1] = true, [2] = true, [7] = true } return { title = "OT value out of range", score = 120, hooks = { "periodic", "end" }, filter = { srv_pool = "PLC" }, check = function(flow) local info = flow.json_info() local setpoint = tonumber(info["OT_SETPOINT"]) -- the names printed by the script above local command = tonumber(info["OT_CMD"]) if setpoint and (setpoint < SETPOINT_MIN or setpoint > SETPOINT_MAX) then flow.triggerAlert("Setpoint " .. setpoint .. " out of range [" .. SETPOINT_MIN .. ", " .. SETPOINT_MAX .. "] on " .. flow.srv()) elseif command and not ALLOWED_COMMANDS[command] then flow.triggerAlert("Unexpected command " .. command .. " to " .. flow.srv()) end end, } The installed examples `proprietary_protocol_range.lua` and `modbus_function_code_rate.lua` (Modbus function codes per minute, over all the flows of a PLC) are in `scripts/callbacks/checks/flows/examples/` under the ntopng installation directory. Testing a script ---------------- 1. Save the script in `/etc/ntopng/custom_checks/flows/` and restart ntopng (or disable and enable again *Flow User Check Script*). Do the same after every change to a script: scripts are read only when they are loaded. 2. Look at the ntopng log (e.g. `journalctl -u ntopng`): you should see `Loaded custom flow script [title: ] on <interface>`. If the script has a mistake, the log says why it was disabled, e.g. `unknown key 'filtr'`, `unknown host pool 'OT devices'`, or the line of a Lua error. 3. While writing, add `print(...)` lines to see what the script receives, e.g. ``print(flow.cli(), flow.srv_port())``: the output goes to the ntopng log. Remove them when the script works, as they slow ntopng down. 4. Generate the traffic and open the Alerts Explorer, *Flow* tab, filter *Custom Script* = the title of your script. Common mistakes: - **Nothing happens**: the filter is too narrow (wrong port, wrong pool name, pool name with different upper/lower case), or the *Flow User Check Script* check is not enabled. - **attempt to concatenate a nil value**: a value joined with `..` is missing; use `tostring(value)` or check it with `if value then ... end` first. - **'=' expected near ...** or **'}' expected near ...**: a comma is missing between two entries of the table. - **attempt to call a nil value (field ...)**: a function name is misspelled, e.g. `flow.server()` instead of `flow.srv()`.