Troubleshooting ​

This section provides solutions to common issues encountered when deploying and operating nEdge Lite.

Startup Issues ​

License Validation Failed ​

Problem: Invalid license or License file not found

Solution:

shell
# Check license file location
ls -la nedgelite.license /etc/nedgelite.license

# Verify license validity
nedgelite --check-license

# Display system ID for license generation
nedgelite --show-system-id

# Contact ntop.org for valid license

Unable to Bind to NFQUEUE ​

Problem: Unable to open queue 0 or Unable to bind to queue

Causes and Solutions:

  1. Queue already in use:

    shell
    # Check for other nedgelite instances
    ps aux | grep nedgelite
    sudo killall nedgelite
    
    # Check for other applications using the queue
    cat /proc/net/netfilter/nfnetlink_queue
  2. Kernel module not loaded:

    shell
    sudo modprobe nfnetlink_queue
    sudo modprobe nf_conntrack
  3. Insufficient permissions:

    shell
    # Must run as root
    sudo nedgelite -q 0 -z tcp://127.0.0.1:1234

Permission Denied Errors ​

Problem: Permission denied when accessing netfilter

Solution:

shell
# Run as root or with sudo
sudo nedgelite -q 0 -z tcp://127.0.0.1:1234

# Check capabilities (if using capabilities instead of root)
sudo setcap cap_net_admin=eip /usr/local/bin/nedgelite

Packet Processing Issues ​

No Packets Reaching nEdge Lite ​

Problem: nEdge Lite starts but shows no activity

Diagnosis:

shell
# Check iptables rules
sudo iptables -t mangle -L -n -v

# Verify packets are being queued
# Look for non-zero packet counts on NFQUEUE rules

# Check queue statistics
cat /proc/net/netfilter/nfnetlink_queue

Solutions:

  1. iptables rules not configured:

    shell
    # Run setup script
    sudo /usr/share/nedgelite/scripts/default_setup.sh eth0
  2. Wrong queue number:

    shell
    # Ensure iptables queue-num matches nedgelite -q option
    sudo iptables -t mangle -L -n -v | grep NFQUEUE
    # Should show: --queue-num 0
    # Must match: nedgelite -q 0
  3. Packets already marked:

    shell
    # Flush conntrack table to reset marks
    sudo conntrack -F
  4. Traffic not matching rules:

    shell
    # Add catch-all rule for testing
    sudo iptables -t mangle -A PREROUTING -j NFQUEUE --queue-num 0 --queue-bypass

Packets Dropped Unexpectedly ​

Problem: Legitimate traffic is being blocked

Diagnosis:

shell
# Run with verbose logging
sudo nedgelite -q 0 -r /etc/nedgelite/policy.json -v

# Check conntrack marks
sudo conntrack -L | grep mark=2

# View blocked flows in ntopng

Solutions:

  1. Overly broad policy rules:

    Review policy file and adjust category/protocol filters:

    json
    {
      "policy": {
        "markers": {
          "categories": {
            "SocialNetwork": "drop"  # May block too much
          }
        },
        "default_marker": "pass"  # Change from "drop"
      }
    }
  2. Protocol misdetection:

    Check nEdge Lite logs to see what protocol was detected. nDPI may occasionally misidentify protocols.

  3. Default marker is "drop":

    json
    "default_marker": "pass"  # More permissive
  4. Testing policies:

    shell
    # Temporarily use pass-all policy
    sudo nedgelite -q 0 -v  # No -r option

High Packet Loss ​

Problem: Packets are being dropped due to queue overflow

Diagnosis:

shell
# Check queue statistics
cat /proc/net/netfilter/nfnetlink_queue
# Look for queue_dropped counter

# Check system logs
dmesg | grep nf_queue

Solutions:

  1. Increase queue size:

    shell
    sudo iptables -t mangle -A PREROUTING -m mark --mark 0 \
      -j NFQUEUE --queue-num 0 --queue-size 4096
  2. Use multiple queues:

    shell
    sudo iptables -t mangle -A PREROUTING -m mark --mark 0 \
      -j NFQUEUE --queue-balance 0:3 --queue-cpu-fanout
    
    sudo nedgelite -q 0:4 -z tcp://127.0.0.1:1234
  3. Add queue-bypass:

    shell
    sudo iptables -t mangle -A PREROUTING -m mark --mark 0 \
      -j NFQUEUE --queue-num 0 --queue-bypass

    This allows packets to pass if nEdge Lite is overloaded or crashes.

  4. Optimize nEdge Lite performance:

    • Reduce flow update interval: -u 60
    • Increase conntrack table size
    • Pin nEdge Lite to dedicated CPU cores

Protocol Detection Issues ​

Protocols Not Being Detected ​

Problem: nDPI marks flows as "Unknown"

Causes:

  • Encrypted traffic (HTTPS, VPN)
  • Not enough packets inspected
  • New/unsupported protocol
  • Fragmented packets

Solutions:

  1. Update nDPI library:

    shell
    cd ~/nDPI
    git pull
    make
    sudo make install
  2. Check nDPI protocol list:

    shell
    nedgelite -H | grep -i <protocol>
  3. Allow more packets for detection:

    nDPI may need 10-20 packets for some protocols. Ensure initial packets aren't being dropped.

  4. Custom protocol configuration:

    Consult nDPI documentation for custom protocol definitions.

Encrypted Traffic ​

Problem: HTTPS/TLS traffic not classified correctly

Explanation: nDPI can detect many protocols over HTTPS using:

  • TLS SNI (Server Name Indication)
  • Certificate analysis
  • Behavioral patterns

Limitations: Some encrypted protocols cannot be identified without TLS interception (MITM).

Wrong Protocol Detected ​

Problem: nDPI misidentifies the protocol

Solutions:

  1. Update nDPI: Newer versions have improved accuracy
  2. Report to nDPI project: Submit PCAP files for analysis
  3. Use category-based policies: Categories are more reliable than individual protocols
  4. Manual override: Use IP-based rules for specific services

Policy Issues ​

Policy Not Applied ​

Problem: Policy rules are not being enforced

Diagnosis:

shell
# Check if policy file is being loaded
sudo nedgelite -q 0 -r /etc/nedgelite/policy.json -v
# Look for "Loading policy" messages

# Verify JSON syntax
cat /etc/nedgelite/policy.json | jq .

Solutions:

  1. JSON syntax error:

    shell
    # Validate JSON
    cat /etc/nedgelite/policy.json | jq .
    # Fix any syntax errors
  2. Pool not matching traffic:

    Verify IP ranges in pool definition:

    json
    {
      "pool": {
        "ip": ["192.168.1.0/24"],  # Must match actual traffic
        ...
      }
    }
  3. Reload policy:

    shell
    sudo kill -HUP $(pidof nedgelite)

Policy Changes Not Taking Effect ​

Problem: Modifications to policy file have no effect

Solutions:

  1. Reload policy:

    shell
    sudo kill -HUP $(pidof nedgelite)
  2. Restart nEdge Lite:

    shell
    sudo killall nedgelite
    sudo nedgelite -q 0 -r /etc/nedgelite/policy.json -z tcp://127.0.0.1:1234
  3. Clear conntrack:

    Existing connections retain old marks:

    shell
    sudo conntrack -F

ntopng Integration Issues ​

No Flows Appearing in ntopng ​

Problem: nEdge Lite is running but ntopng shows no flows

Diagnosis:

shell
# Check ZMQ connection
sudo netstat -tn | grep 1234

# Verify ntopng endpoint
ps aux | grep ntopng | grep tcp://

Solutions:

  1. Endpoint mismatch:

    shell
    # ntopng must have trailing 'c'
    sudo ntopng -i tcp://127.0.0.1:1234c
    
    # nEdge Lite must NOT have trailing 'c'
    sudo nedgelite -q 0 -z tcp://127.0.0.1:1234
  2. Firewall blocking ZMQ:

    shell
    # Allow TCP port 1234
    sudo iptables -A INPUT -p tcp --dport 1234 -j ACCEPT
  3. ntopng not running:

    shell
    ps aux | grep ntopng
    # Start ntopng if not running

ZMQ Connection Refused ​

Problem: Connection refused when nEdge Lite tries to connect to ntopng

Solutions:

  1. Start ntopng first:

    shell
    sudo ntopng -i tcp://0.0.0.0:1234c
  2. Check ntopng is listening:

    shell
    sudo netstat -tnlp | grep 1234
  3. Verify endpoint address:

    • Use 0.0.0.0 on ntopng to listen on all interfaces
    • Use correct IP address in nEdge Lite -z option

Policy Updates from ntopng Not Working ​

Problem: Changes in ntopng GUI don't affect nEdge Lite

Solutions:

  1. Verify policy endpoint:

    shell
    # ntopng must publish events
    sudo ntopng -i tcp://0.0.0.0:5556c --zmq-publish-events tcp://0.0.0.0:5557
    
    # nEdge Lite must subscribe
    sudo nedgelite -q 0 -z tcp://ntopng:5556 -p tcp://ntopng:5557
  2. Check ZMQ policy connection:

    shell
    sudo netstat -tn | grep 5557
  3. Restart both services:

    shell
    sudo killall ntopng nedgelite
    # Start ntopng first, then nEdge Lite

Performance Issues ​

High CPU Usage ​

Problem: nEdge Lite consuming excessive CPU

Causes:

  • High packet rate
  • Complex policies
  • Too frequent flow updates

Solutions:

  1. Use multiple queues:

    shell
    sudo nedgelite -q 0:$(nproc) -z tcp://127.0.0.1:1234
  2. Reduce flow update frequency:

    shell
    sudo nedgelite -q 0 -z tcp://127.0.0.1:1234 -u 60
  3. Optimize policies:

    • Use category filters instead of many protocol filters
    • Simplify policy logic
  4. System tuning:

    shell
    # Increase conntrack table
    sudo sysctl -w net.netfilter.nf_conntrack_max=1048576

High Memory Usage ​

Problem: nEdge Lite memory usage growing over time

Diagnosis:

shell
# Monitor memory
ps aux | grep nedgelite
pmap $(pidof nedgelite)

Causes:

  • Large number of concurrent flows
  • Flow leaks (not being purged)

Solutions:

  1. Normal behavior: ~2-3KB per active flow is expected

  2. Adjust idle timeout: If flows aren't being purged, check conntrack timeouts:

    shell
    sudo sysctl -w net.netfilter.nf_conntrack_tcp_timeout_established=3600
  3. Monitor flow count:

    shell
    sudo conntrack -C  # Show connection count

Network Latency ​

Problem: Increased latency when nEdge Lite is running

Solutions:

  1. Optimize queue processing:

    • Use --queue-cpu-fanout in iptables
    • Pin nEdge Lite to dedicated cores
  2. Disable flow batching:

    shell
    sudo nedgelite -q 0 -z tcp://127.0.0.1:1234 -f
  3. Check queue depth:

    shell
    cat /proc/net/netfilter/nfnetlink_queue

System Issues ​

Kernel Module Not Loading ​

Problem: modprobe: FATAL: Module nfnetlink_queue not found

Solutions:

shell
# Install kernel modules
# Ubuntu/Debian
sudo apt-get install linux-headers-$(uname -r)

# CentOS/Rocky
sudo yum install kernel-devel-$(uname -r)

# Rebuild modules
sudo depmod -a
sudo modprobe nfnetlink_queue

Conntrack Table Full ​

Problem: nf_conntrack: table full, dropping packet

Solutions:

shell
# Increase conntrack table size
sudo sysctl -w net.netfilter.nf_conntrack_max=1048576

# Make persistent
echo "net.netfilter.nf_conntrack_max=1048576" | \
  sudo tee -a /etc/sysctl.conf

# Verify
sudo sysctl -p

Out of Memory ​

Problem: Kernel OOM killer terminates nEdge Lite

Solutions:

  1. Add more RAM

  2. Reduce flow count: Implement aggressive timeout policies

  3. Limit nEdge Lite memory:

    shell
    # Use systemd to limit memory
    sudo systemctl set-property nedgelite.service MemoryMax=1G

Debugging Techniques ​

Verbose Logging ​

shell
sudo nedgelite -q 0 -r /etc/nedgelite/policy.json -z tcp://127.0.0.1:1234 -v

Packet Capture ​

shell
# Capture packets going to NFQUEUE
sudo tcpdump -i any -w /tmp/capture.pcap

# Analyze with Wireshark
wireshark /tmp/capture.pcap

Conntrack Monitoring ​

shell
# Watch connections in real-time
watch -n 1 'sudo conntrack -L | head -20'

# Show statistics
sudo conntrack -S

# Show connections with marks
sudo conntrack -L -m

iptables Rule Verification ​

shell
# List mangle table with counters
sudo iptables -t mangle -L -n -v

# Trace packet path (requires iptables-extensions)
sudo iptables -t raw -A PREROUTING -p tcp --dport 80 -j TRACE
sudo xtables-monitor -t

System Logs ​

shell
# Check kernel messages
sudo dmesg | grep -i "nf_queue\|conntrack\|nedgelite"

# Check system logs
sudo journalctl -u nedgelite -f  # If running as systemd service

Getting Help ​

If you cannot resolve an issue:

  1. Check Documentation: Review relevant sections of this guide

  2. Search Issues: Look for similar issues on GitHub

  3. Collect Diagnostics:

    shell
    # System info
    uname -a
    nedgelite --version
    ntopng --version
    
    # Configuration
    iptables -t mangle -L -n -v
    cat /etc/nedgelite/policy.json
    ps aux | grep nedgelite
    
    # Statistics
    conntrack -S
    cat /proc/net/netfilter/nfnetlink_queue
  4. Report Bug: https://github.com/ntop/nEdge Lite/issues

Include:

  • nEdge Lite version
  • Operating system and kernel version
  • Configuration files
  • Log output with -v flag
  • Steps to reproduce
  1. Commercial Support: Contact ntop.org for professional support

Next Steps ​

Documentation of the ntop open source tools.