4.1. Writing Custom Flow Scripts: Guide and Examples
This page explains, step by step, how a custom flow script is made and then shows ready-to-use examples, from the simplest to the more complete ones. Copy an example, change the values marked in the comments, save it in /etc/ntopng/custom_checks/flows/ and restart ntopng.
The full list of options and functions is in Flow Checks.
4.1.1. How a script works
ntopng looks at every flow (a conversation between a client and a server). For each flow, it asks your script: “is there something wrong here?”. Your script answers by calling flow.triggerAlert(“message”) when it finds a problem, or by doing nothing when the flow is fine.
A script has two parts:
Which flows to look at (filter): e.g. only Modbus, only port 502, only the hosts of the pool OT Devices. ntopng applies the filter for you, very quickly, and gives the script only these flows.
What to check (check): a few lines that read the flow (its addresses, ports, bytes, protocol…) and decide whether to raise the alert.
The smallest working script is:
return {
title = "Telnet in use",
filter = { srv_port = 23 },
check = function(flow)
flow.triggerAlert("Telnet connection to " .. flow.srv())
end,
}
Read it as: “for every flow towards port 23, raise the alert Telnet in use with the message Telnet connection to <server IP>”. The filter does all the work, the check only raises the alert.
4.1.2. Lua in five minutes
You need very little Lua to write a script. This is all of it:
-- Two dashes start a comment: ntopng ignores the rest of the line.
-- A variable: a name that holds a value. Always write "local" in front of it.
local max_bytes = 1000000 -- a number
local plc_address = "10.0.0.5" -- a text (string), always in quotes
-- Join texts with two dots
local message = "Too much traffic to " .. plc_address
-- Compare: == (equal), ~= (different, NOT !=), <, >, <=, >=
-- Combine conditions with: and, or, not
if flow.bytes() > max_bytes and flow.srv() == plc_address then
flow.triggerAlert(message)
end -- every "if" closes with "end"
-- if / elseif / else
if flow.srv_port() == 502 then
-- ...
elseif flow.srv_port() == 102 then
-- ...
else
-- ...
end
-- A list of allowed values (a "set"): the value in square brackets, then "= true"
local allowed_clients = {
["10.0.0.10"] = true,
["10.0.0.11"] = true,
}
if not allowed_clients[flow.cli()] then -- true when the client is NOT in the list
flow.triggerAlert("Client not allowed: " .. flow.cli())
end
Things to remember:
Inside return { … } every entry ends with a comma: title = “…”, score = 100, check = function(flow) … end,
Texts go in double quotes; numbers do not (502, not “502”).
function(flow) … end, if … then … end, for … do … end: every block closes with end.
Upper and lower case matter: flow.srv() works, flow.SRV() does not.
A value that is not there is nil. Joining nil to a text is an error: use tostring(value) when a value may be missing, e.g. “Query: “ .. tostring(query).
4.1.3. Choosing the flows: the filter
The filter is the most important part: it decides which flows reach the script, and it is evaluated by ntopng at no cost. Write as narrow a filter as you can.
filter = {
srv_port = 502, -- server port 502
ip = { "10.10.0.0/16", "192.168.1.5" }, -- client or server in 10.10.0.0/16, or 192.168.1.5
pool = "OT Devices", -- client or server in the host pool "OT Devices"
},
Rules:
Every field you write must match (it is an AND): the example selects the flows on port 502 and with an address in the list and with a host in the pool.
A field with a list matches when any of its values does (it is an OR): srv_port = { 502, 503 } is port 502 or 503.
Fields you do not write match every flow. A script without filter receives all the flows: avoid it.
Available fields: cli_ip, srv_ip, ip, cli_port, srv_port, port, l4_proto, l7_proto, cli_pool, srv_pool, pool. cli_ means the client, srv_ the server, no prefix either of them.
exclude has the same fields and does the opposite: the flows matching it are skipped. For instance
exclude = { cli_ip = "10.0.0.250" } ignores the flows of a monitoring server.
Host pools can be written by name (“OT Devices”, exactly as shown in Pools > Host Pools, upper and lower case included) or by number (the pool id, e.g. 3). The hosts that are not in any pool belong to the Default pool (id 0). The names are read when the script is loaded: after creating or renaming a pool, disable and enable again Flow User Check Script (or restart ntopng) so that the scripts are loaded again. A pool name that does not exist disables the script, and the ntopng log says so.
4.1.4. When to run: the hooks
hooks says when ntopng calls the script for a flow:
detected: once, when ntopng recognises the application protocol of the flow (at the start of the flow).
periodic: every few seconds while the flow is active.
end: once, when the flow ends.
Without hooks the script runs on all three. Use detected to count connections (each flow counts once), and periodic / end to check values that grow during the flow (bytes, function codes). A script that calls flow.triggerAlert several times on the same flow does not create duplicate alerts.
4.1.5. Examples
Each example is a complete file. Save it with a name ending in .lua, e.g. /etc/ntopng/custom_checks/flows/ot_internet.lua.
4.1.5.1. Example 1: OT devices talking to the Internet
The PLCs are in the host pool OT Devices: they must only talk inside the plant. Alert when one of them, as a client, contacts a remote (non local) host.
return {
title = "OT device contacts the Internet",
score = 100,
hooks = { "detected" },
filter = { cli_pool = "OT Devices" }, -- change it to the name of your pool
check = function(flow)
-- "local@remote": local client, remote server
if flow.direction() == "local@remote" then
flow.triggerAlert("OT device " .. flow.cli() .. " contacted " .. flow.srv() .. ":" .. flow.srv_port())
end
end,
}
4.1.5.2. Example 2: only allowed clients may talk to the PLCs
The PLCs are in the pool PLC, and only the two engineering workstations may connect to them.
-- The workstations allowed to connect to the PLCs
local ALLOWED_CLIENTS = {
["10.0.0.10"] = true,
["10.0.0.11"] = true,
}
return {
title = "Unauthorised access to PLC",
score = 150,
hooks = { "detected" },
filter = { srv_pool = "PLC" },
check = function(flow)
if not ALLOWED_CLIENTS[flow.cli()] then
flow.triggerAlert(flow.cli() .. " connected to PLC " .. flow.srv() .. " on port " .. flow.srv_port())
end
end,
}
4.1.6. Counting over time: counter
Many detections are “too many times in a while”: too many connections per minute, a command repeated too often. A single flow does not know about the other flows, so every script receives a ready-made helper, counter, that keeps counts across flows. Nothing to install or require: it is always there.
- counter.inc(key, seconds [, amount])Adds amount (default 1) to the counter called key and returns its new value. The counter starts from 0 and is cleared seconds after its first inc (default 60): then the count starts again from 0.
- counter.get(key)The current value of key, without changing it (0 when it was never used or has been cleared).
- counter.reset(key)Clears key now.
The key is a text you choose, and decides what is counted. Build it from the flow:
counter.inc(flow.cli(), 60) -- per client, in 1 minute
counter.inc(flow.srv(), 3600) -- per server, in 1 hour
counter.inc(flow.cli() .. ">" .. flow.srv(), 60) -- per client-server pair, in 1 minute
counter.inc(flow.srv() .. "/fc65", 60, 10) -- add 10 to the "function code 65 on this server" count
Good to know:
The time window is fixed, not sliding: with 60 seconds, a count that starts at 10:00:20 is cleared at 10:01:20.
Each script has its own counters: two scripts using the same key do not see each other’s counts. The counters are also kept per interface, and they are cleared when the scripts are loaded again.
Use the hook detected when counting flows (each flow is counted once). The installed example modbus_function_code_rate.lua shows how to count the Modbus function codes of all the flows of a PLC.
4.1.6.1. Example 3: too many connections per minute
Alert when a client opens more than 30 Modbus connections in one minute (a scan or a misbehaving HMI). The key is the client address, so each client has its own counter. The hook is detected, so that each flow is counted once.
local MAX_CONNECTIONS_PER_MINUTE = 30
return {
title = "Modbus connection burst",
hooks = { "detected" },
filter = { srv_port = 502, l4_proto = "TCP" },
check = function(flow)
local connections = counter.inc(flow.cli(), 60)
if connections > MAX_CONNECTIONS_PER_MINUTE then
flow.triggerAlert(flow.cli() .. " opened " .. connections .. " Modbus connections in the last minute")
end
end,
}
4.1.7. OT protocols
In a typical OT installation nProbe analyses the traffic of the plant and sends the flows to ntopng, with the information of the OT protocols. A script reads it in two ways:
flow.ot(): the OT protocols known to ntopng (Modbus, S7Comm, PROFINET, IEC 60870-5-104), always with the same structure, both for the flows sent by nProbe and for the traffic captured by ntopng.
flow.json_info(): any other field nProbe sends with the flow, e.g. the fields that an nDPI plugin adds to an OT protocol on the nProbe side (see Example 6).
This is what flow.ot() returns for a Modbus flow (the numbers are the totals since the flow started):
{
modbus = {
function_codes = { ["3"] = 20, ["65"] = 150 }, -- function code -> number of uses
function_codes_transitions = { ["3,65"] = 10 }, -- "from,to" -> number of times
registers = { ["100"] = 12, ["40001"] = 3 }, -- register -> number of uses
num_exceptions = 7, -- exceptions (errors) returned
}
}
S7Comm (flow.ot().s7comm) has function_codes, function_codes_transitions and num_exceptions; PROFINET (flow.ot().profinet) also has operations (requests, responses ok and responses with errors per operation). A protocol that is not in the flow is nil: always check it, as in the examples below.
Warning
The function codes, transitions and registers are texts in quotes: write function_codes["65"].
function_codes[65] (without quotes) is always nil, so the script never raises the alert.
The values grow while the flow is active: use the hooks periodic and end, so the script sees the updated values. The same alert is not repeated on the same flow.
4.1.7.1. Example 4: too many Modbus exceptions
Alert when a PLC returns more than 5 exceptions in a flow: a client is sending wrong commands, or the PLC is failing.
local MAX_EXCEPTIONS = 5
return {
title = "Too many Modbus exceptions",
score = 80,
hooks = { "periodic", "end" },
filter = { l7_proto = "Modbus", srv_pool = "PLC" },
check = function(flow)
local modbus = flow.ot().modbus
if not modbus then return end -- no Modbus information (yet)
if modbus.num_exceptions > MAX_EXCEPTIONS then
flow.triggerAlert(modbus.num_exceptions .. " Modbus exceptions from " .. flow.srv())
end
end,
}
4.1.7.2. Example 5: a function code used too much, or one that must never be used
Two rules in one script: some Modbus function codes are allowed only up to a number of uses per flow, others must never be seen.
-- Function code (in quotes) -> maximum number of uses in a flow
local MAX_USES = {
["6"] = 50, -- Write Single Register
["16"] = 20, -- Write Multiple Registers
}
-- Function codes that must never be used
local FORBIDDEN = {
["8"] = "Diagnostics",
["65"] = "vendor command 65",
}
return {
title = "Modbus function code not allowed",
score = 120,
hooks = { "periodic", "end" },
filter = { l7_proto = "Modbus" },
check = function(flow)
local modbus = flow.ot().modbus
if not modbus then return end
for code, uses in pairs(modbus.function_codes) do
if FORBIDDEN[code] then
flow.triggerAlert("Forbidden function code " .. code .. " (" .. FORBIDDEN[code] .. ") sent to " .. flow.srv())
return
end
if MAX_USES[code] and uses > MAX_USES[code] then
flow.triggerAlert("Function code " .. code .. " used " .. uses .. " times (max " .. MAX_USES[code] .. ")")
return
end
end
end,
}
S7Comm works the same way: use flow.ot().s7comm and filter = { l7_proto = "S7Comm" }. For instance the S7
function codes "40" (PLC Control) and "41" (PLC Stop) start and stop the PLC program and, outside
maintenance, must never be seen.
4.1.7.3. Example 6: fields added by nProbe plugins
When an nProbe plugin (or an nDPI plugin on the nProbe side) adds fields to an OT protocol, the script reads them with flow.json_info(), by the name nProbe gives them. The field names depend on the plugin: to find them, use this script once, read the names in the ntopng log, then delete it.
return {
title = "Show the probe fields",
hooks = { "end" },
filter = { srv_port = 502 }, -- the flows you are interested in
check = function(flow)
for name, value in pairs(flow.json_info()) do
print(name .. " = " .. tostring(value))
end
end,
}
The log shows lines such as OT_SETPOINT = 812. Then check the field: tonumber turns it into a number (the probe may send numbers as texts), and is nil when the field is missing.
local SETPOINT_MIN, SETPOINT_MAX = 0, 500
local ALLOWED_COMMANDS = { [1] = true, [2] = true, [7] = true }
return {
title = "OT value out of range",
score = 120,
hooks = { "periodic", "end" },
filter = { srv_pool = "PLC" },
check = function(flow)
local info = flow.json_info()
local setpoint = tonumber(info["OT_SETPOINT"]) -- the names printed by the script above
local command = tonumber(info["OT_CMD"])
if setpoint and (setpoint < SETPOINT_MIN or setpoint > SETPOINT_MAX) then
flow.triggerAlert("Setpoint " .. setpoint .. " out of range [" .. SETPOINT_MIN .. ", " .. SETPOINT_MAX .. "] on " .. flow.srv())
elseif command and not ALLOWED_COMMANDS[command] then
flow.triggerAlert("Unexpected command " .. command .. " to " .. flow.srv())
end
end,
}
The installed examples proprietary_protocol_range.lua and modbus_function_code_rate.lua (Modbus function codes per minute, over all the flows of a PLC) are in scripts/callbacks/checks/flows/examples/ under the ntopng installation directory.
4.1.8. Testing a script
Save the script in /etc/ntopng/custom_checks/flows/ and restart ntopng (or disable and enable again Flow User Check Script). Do the same after every change to a script: scripts are read only when they are loaded.
Look at the ntopng log (e.g. journalctl -u ntopng): you should see Loaded custom flow script <file> [title: <title>] on <interface>. If the script has a mistake, the log says why it was disabled, e.g. unknown key ‘filtr’, unknown host pool ‘OT devices’, or the line of a Lua error.
While writing, add print(…) lines to see what the script receives, e.g.
print(flow.cli(), flow.srv_port()): the output goes to the ntopng log. Remove them when the script works, as they slow ntopng down.Generate the traffic and open the Alerts Explorer, Flow tab, filter Custom Script = the title of your script.
Common mistakes:
Nothing happens: the filter is too narrow (wrong port, wrong pool name, pool name with different upper/lower case), or the Flow User Check Script check is not enabled.
attempt to concatenate a nil value: a value joined with .. is missing; use tostring(value) or check it with if value then … end first.
‘=’ expected near … or ‘}’ expected near …: a comma is missing between two entries of the table.
attempt to call a nil value (field …): a function name is misspelled, e.g. flow.server() instead of flow.srv().